+# Net classes
+
+Use one net-class table for every board in a repo, kept in one file and written into each project by `tools/netclasses.py`. Modules are pasted onto shared base boards as design blocks, so their classes must not drift or clash. The router takes its track widths from these classes too.
+
+## Use
+
+``` sh
+python3 tools/netclasses.py modules/*/*.kicad_pro libraries/templates/*/*.kicad_pro # write
+python3 tools/netclasses.py --check modules/*/*.kicad_pro # report drift
+python3 tools/netclasses.py --table other.json board.kicad_pro
+```
+
+The table is `netclasses.json` at the repo root. Without it the script uses a small generic default (Ethernet, USB, Power, Ground, Default 0.2 mm). Format:
+
+``` json
+{
+ "clearance": 0.2, "via": 0.6, "drill": 0.3, "default_width": 0.2,
+ "track_widths": [0.2, 0.25, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0],
+ "classes": {
+ "Ethernet": [0.25, 0.25, 0.2, ["*/ETH_TX?", "*/ETH_RX?"]],
+ "Bus": [1.0, null, null, ["+3V3", "+5V", "+24V"]],
+ "Power": [0.5, null, null, ["*/3V3", "*/VBUS", "Net-(*-SW)"]],
+ "Ground": [0.4, null, null, ["GND"]]
+ }
+}
+```
+
+Each class is `[track width, diff-pair width, diff-pair gap, patterns]`, listed in priority order. The script writes `net_settings.classes`, `netclass_patterns`, and the track-width, via and diff-pair palettes. All other project settings stay as they are. `tools/din_template.py` applies the table to new templates.
+
+Close the project in KiCad first. An open editor writes its own copy back on save, and reverting the board does not reload net classes.
+
+## Rules
+
+- **One source.** Edit the table, then write it into every project.
+- **Sheet-independent patterns:** `*/RTD_COM`, not `/My Sheet/RTD_COM`. The same list then works in a module's test project and on the base board under any sheet name.
+ - Global power nets (`+3V3`, `GND`) match by name.
+ - Auto-named nets use wildcards for the reference, e.g. `Net-(*-SW)` for any buck switch node. Better still, give such nets a label.
+- **Names are reserved repo-wide.** Module-specific classes live in the same table. A pattern that matches nothing does no harm, and no other module can reuse a name with other widths.
+- **Widths are defaults, not minimums.** Short, narrower escapes (e.g. 0.2 mm out of a small pad) stay legal. Keep a margin over the fab's minimum: 0.2 mm on two layers, where 0.10 mm is a typical minimum.
+- **Pattern matching:** KiCad matches patterns against the whole net name. When several match, the lower `priority` (earlier in the table) wins.
+
+## Sizing hints
+
+- **Supply bus** carrying about 2 A: 1.0 mm of 35 µm outer copper carries about 2 A at 10 °C rise (IPC-2221).
+- **Local rails** of a few hundred mA: 0.5 mm keeps the drop and inductance low.
+- **Field lines at screw terminals** (0–10 V, tach, digital outputs, RS-485): about 0.4 mm. The signals are small, but ESD and surge currents run from the terminal to the TVS.
+- **Ethernet 10/100 and full-speed USB** on short runs (< 20 mm) need no impedance control on a 2-layer board. The classes exist so that the pairs route together.