- Panasonic Aquarea J (WH-MDC05/07/09J3E5) and L (WH-WDG05/07/09LE5)
monobloc capacity and COP tables from the service manuals.
- Optional hot water (daily demand charged 11-15 h MEZ with priority over
heating) and PV with battery from DWD 10-minute global/diffuse irradiation,
each switched on separately; surplus fed in or curtailed.
- Inputs in five steps with the key figures always visible on top and the
matching chart beside each step; full results in the last step.
- Bisect the bivalence point so no hour at exactly that temperature is left
uncovered (seen with 1 K bins).
- Average the duration curve between sample points instead of picking
single hours, which showed hot water hours as spikes.
- Make the hidden attribute override label display rules.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Diffstat (limited to 'web/index.html')
| -rw-r--r-- | web/index.html | 136 |
1 files changed, 112 insertions, 24 deletions
diff --git a/web/index.html b/web/index.html index bc22366..d3a0dbf 100644 --- a/web/index.html +++ b/web/index.html @@ -12,8 +12,16 @@ <p>Heizwärmebedarf und Aufteilung Wärmepumpe / Zusatzheizung für jede Postleitzahl in Deutschland, auf Basis stündlicher DWD-Messwerte 2007–2025.</p> </header> +<div id="preview" class="preview"> + <div id="previewKpis" class="kpis compact"></div> + <div id="status" class="hint">Lade Daten …</div> +</div> + +<nav id="stepper" class="stepper" aria-label="Schritte"></nav> + <main> - <form id="form" autocomplete="off"> +<form id="form" autocomplete="off"> + <section class="step" data-step="1" data-title="Standort" hidden> <fieldset> <legend>Standort</legend> <label>Postleitzahl @@ -24,7 +32,9 @@ <select id="scenario"></select> </label> </fieldset> - + <aside id="aside-1" class="step-aside"></aside> + </section> + <section class="step" data-step="2" data-title="Gebäude" hidden> <fieldset> <legend>Gebäude</legend> <label>Norm-Heizlast <span class="unit">kW</span> @@ -40,7 +50,9 @@ </select> </label> </fieldset> - + <aside id="aside-2" class="step-aside"></aside> + </section> + <section class="step" data-step="3" data-title="Wärmepumpe" hidden> <fieldset> <legend>Wärmepumpe</legend> <label>Typ @@ -53,9 +65,21 @@ </label> <label id="deviceField">Gerät <select id="device"> - <option value="lwm80">Remko LWM 80</option> - <option value="lwm110" selected>Remko LWM 110</option> - <option value="lwm150">Remko LWM 150</option> + <optgroup label="Remko"> + <option value="lwm80">Remko LWM 80</option> + <option value="lwm110" selected>Remko LWM 110</option> + <option value="lwm150">Remko LWM 150</option> + </optgroup> + <optgroup label="Panasonic Aquarea J"> + <option value="mdc05j">WH-MDC05J3E5 (5 kW)</option> + <option value="mdc07j">WH-MDC07J3E5 (7 kW)</option> + <option value="mdc09j">WH-MDC09J3E5 (9 kW)</option> + </optgroup> + <optgroup label="Panasonic Aquarea L (R290)"> + <option value="wdg05l">WH-WDG05LE5 (5 kW)</option> + <option value="wdg07l">WH-WDG07LE5 (7 kW)</option> + <option value="wdg09l">WH-WDG09LE5 (9 kW)</option> + </optgroup> <option value="generic">Generisch (Leistung über Bivalenzpunkt)</option> </select> </label> @@ -80,7 +104,7 @@ <input id="flowN" type="number" step="1" min="25" max="65" value="35"> </label> <label class="check"><input id="flowCurve" type="checkbox" checked> witterungsgeführt (Heizkurve)</label> - <div class="hint">Vorlauf sinkt linear bis 20 °C bei 20 °C Außentemperatur, mindestens 25 °C. Leistung und COP der Remko-Geräte nach Montageanleitung (W35/W45/W55, Volllast), außerhalb davon über den Carnot-Gütegrad übertragen. Ohne Teillast, Umwälzpumpe und Warmwasser.</div> + <div class="hint">Vorlauf sinkt linear bis 20 °C bei 20 °C Außentemperatur, mindestens 25 °C. Leistung und COP der Geräte nach Herstellerangaben (Remko: Montageanleitung, Panasonic: Service-Manual; W35/W45/W55, Volllast), außerhalb davon über den Carnot-Gütegrad übertragen. Ohne Teillast und Umwälzpumpe.</div> <details> <summary>Erweitert</summary> <div id="slopeField"> @@ -98,7 +122,38 @@ </label> </details> </fieldset> - + <aside id="aside-3" class="step-aside"></aside> + </section> + <section class="step" data-step="4" data-title="Warmwasser & PV" hidden> + <fieldset> + <legend>Warmwasser & PV</legend> + <label class="check"><input id="wwOn" type="checkbox"> Warmwasser mitrechnen</label> + <div id="wwFields" hidden> + <label>Warmwasserbedarf <span class="unit">kWh/Tag</span> + <input id="ww" type="number" step="0.5" min="0" value="6"> + </label> + <div class="hint">Wärme inklusive Speicherverlusten, etwa 1,5 kWh pro Person und Tag.</div> + <label>Speichertemperatur <span class="unit">°C</span> + <input id="wwTemp" type="number" step="1" min="40" max="60" value="50"> + </label> + <div class="hint">Geladen wird täglich von 11 bis 15 Uhr (MEZ) mit 5 K über Speichertemperatur, vorrangig vor der Heizung. Was die WP nicht schafft, übernimmt die Zusatzheizung, unterhalb des Bivalenzpunkts auch die dadurch fehlende Heizleistung.</div> + </div> + <label class="check"><input id="pvOn" type="checkbox"> PV und Speicher mitrechnen</label> + <div id="pvFields" hidden> + <label>PV-Anlage <span class="unit">kWp</span> + <input id="kwp" type="number" step="0.1" min="0" value="8"> + </label> + <label>Batteriespeicher <span class="unit">kWh</span> + <input id="battery" type="number" step="0.5" min="0" value="5"> + </label> + <label class="check"><input id="feedOn" type="checkbox" checked> Überschuss einspeisen</label> + <div class="hint">Vergütung unter Kosten. Ohne Einspeisung wird der Überschuss abgeregelt.</div> + <div class="hint" id="pvHint">Süd, 30° Neigung, 14 % Systemverluste, Modultemperatur aus der Lufttemperatur. Speicher mit 90 % Zykluswirkungsgrad, Lade- und Entladeleistung bis 1 C. PV und Speicher versorgen nur WP und Heizstab, kein Haushaltsstrom.</div> + </div> + </fieldset> + <aside id="aside-4" class="step-aside"></aside> + </section> + <section class="step" data-step="5" data-title="Kosten" hidden> <fieldset> <legend>Kosten</legend> <label>Strompreis Wärmepumpe <span class="unit">ct/kWh</span> @@ -121,31 +176,64 @@ <input id="effBackup" type="number" step="1" min="1" max="110" value="100"> </label> <div class="hint" id="fuelHint"></div> + <label id="feedInField" hidden>Einspeisevergütung <span class="unit">ct/kWh</span> + <input id="feedIn" type="number" step="0.01" min="0" value="7.8"> + </label> </fieldset> - </form> + </section> +</form> - <section id="results" aria-live="polite"> - <div id="status" class="hint">Lade Daten …</div> + <section id="results" class="step results" data-step="6" data-title="Ergebnisse" aria-live="polite" hidden> + <div id="summaryBlock"> + <h2>Heizung und Warmwasser</h2> + <div id="summaryKpis" class="kpis"></div> + </div> + <h2>Heizung</h2> <div id="kpis" class="kpis"></div> - <figure> - <figcaption>Jahresdauerlinie der Heizlast</figcaption> - <div id="duration" class="chart"></div> - </figure> - <figure> - <figcaption>Heizwärme je Außentemperatur (1-K-Bins)</figcaption> - <div id="bins" class="chart"></div> - </figure> - <figure> - <figcaption>Heizwärme je Monat</figcaption> - <div id="months" class="chart"></div> - </figure> + <div id="figs-heating" class="figs"></div> + <div id="extraBlock"> + <h2 id="extraHeading">Warmwasser & PV</h2> + <div id="extraKpis" class="kpis"></div> + <div id="figs-extra" class="figs"></div> + </div> <div class="actions"> <button type="button" id="exportBins">Bins als CSV</button> <button type="button" id="exportHours">Stundenwerte als CSV</button> </div> - <p class="hint">Vereinfachtes Modell: Heizlast linear zwischen Norm-Heizlast bei Norm-Außentemperatur und 0 bei Heizgrenztemperatur, ohne Warmwasser. Wetterdaten: Deutscher Wetterdienst (DWD Climate Data Center, Stundenwerte Lufttemperatur), Postleitzahlen: GeoNames (CC BY 4.0). Die Norm-Außentemperatur der Station ist eine Schätzung aus den Messdaten, nicht der Wert nach DIN/TS 12831-1.</p> </section> + + <div id="figures" hidden> + <figure data-step="2" data-group="heating"> + <figcaption>Jahresdauerlinie der Heizlast</figcaption> + <div id="duration" class="chart"></div> + </figure> + <figure data-step="3" data-group="heating"> + <figcaption>Heizwärme je Außentemperatur (1-K-Bins)</figcaption> + <div id="bins" class="chart"></div> + </figure> + <figure data-step="1" data-group="heating"> + <figcaption>Heizwärme je Monat</figcaption> + <div id="months" class="chart"></div> + </figure> + <figure data-step="4" data-group="extra" id="powerFigure"> + <figcaption>Strom je Monat (WP und Heizstab)</figcaption> + <div id="power" class="chart"></div> + </figure> + <figure data-step="4" data-group="extra" id="wwFigure"> + <figcaption>Warmwasser je Monat</figcaption> + <div id="wwMonths" class="chart"></div> + </figure> + </div> + + <div class="step-nav"> + <button type="button" id="prev">Zurück</button> + <button type="button" id="next" class="primary">Weiter</button> + </div> </main> + +<footer> + <p class="hint">Vereinfachtes Modell: Heizlast linear zwischen Norm-Heizlast bei Norm-Außentemperatur und 0 bei Heizgrenztemperatur. Wetterdaten: Deutscher Wetterdienst (DWD Climate Data Center, Stundenwerte Lufttemperatur, 10-Minuten-Werte Global- und Diffusstrahlung), Postleitzahlen: GeoNames (CC BY 4.0). Die Norm-Außentemperatur der Station ist eine Schätzung aus den Messdaten, nicht der Wert nach DIN/TS 12831-1.</p> +</footer> <script src="devices.js"></script> <script src="app.js"></script> </body> |