Add Remko LWM 80/110/150 capacity and COP curves
Capacity (n-max) and COP per outdoor and flow temperature from the installation manual. With a device the bivalence point follows from capacity and load (manual switching temperature in alternative mode); load not covered above it is reported separately, cycling hours below the minimum capacity are counted. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Diffstat (limited to 'README.md')
-rw-r--r--README.md19
1 files changed, 12 insertions, 7 deletions
diff --git a/README.md b/README.md
index 275e3a2..bd66ed4 100644
--- a/README.md
+++ b/README.md
@@ -4,11 +4,15 @@ Like BWP WPsim, but for every German postcode. Hourly DWD air temperatures 2007â
(about 470 stations, nearest station per postcode) drive a simple model:
- Heating load linear from Norm-Heizlast at Norm-Außentemperatur to 0 at the heating limit.
-- Heat pump capacity equals the load at the (manual) bivalence point and changes by a
- fixed %/K with outdoor temperature. Modes: monovalent, bivalent-parallel (optional
- cut-off temperature), bivalent-alternativ.
-- COP from the Remko LWM 110 datasheet (A−7/A2/A7 at W35), transferred to other flow
- temperatures via the Carnot efficiency; flow temperature fixed or weather-compensated.
+- Heat pumps: Remko LWM 80/110/150 with maximum capacity and COP per outdoor and flow
+ temperature (W35/W45/W55) from the installation manual, see `web/devices.js`. The
+ bivalence point follows from capacity and load; in bivalent-alternativ mode it is a
+ manual switching temperature. Load the heat pump cannot cover above it is shown as
+ uncovered. Hours below the minimum capacity are counted as cycling.
+- Generic heat pump: capacity equals the load at a manual bivalence point and changes by a
+ fixed %/K; COP of the LWM 110 (air) or Carnot-based (ground/water).
+- Modes: monovalent (heater rod), bivalent-parallel (optional cut-off temperature),
+ bivalent-alternativ. Flow temperature fixed or weather-compensated.
- Backup fuel: heater rod, natural gas, LPG, oil, pellets or firewood, with amounts in kWh, m³, l, kg or rm.
- Results: heat demand, coverage shares, JAZ, electricity, costs; charts and CSV export.
@@ -52,8 +56,9 @@ fetch fresh data (for example after DWD publishes a new year).
- No altitude correction between postcode and station.
- JAZ ignores cycling, circulation pump and hot water, so it is on the optimistic side.
-- LWM 110 datasheet values were taken from retailer listings; check them against the
- manufacturer's datasheet.
+- Device data is full load at nominal conditions; part load, defrost beyond the datasheet
+ points and other devices are not modelled. Capacities were digitised from the manual's
+ diagrams (about ±0.2 kW).
- Not affiliated with BWP, Remko or DWD.
## License and data sources