- Panasonic Aquarea J (WH-MDC05/07/09J3E5) and L (WH-WDG05/07/09LE5)
monobloc capacity and COP tables from the service manuals.
- Optional hot water (daily demand charged 11-15 h MEZ with priority over
heating) and PV with battery from DWD 10-minute global/diffuse irradiation,
each switched on separately; surplus fed in or curtailed.
- Inputs in five steps with the key figures always visible on top and the
matching chart beside each step; full results in the last step.
- Bisect the bivalence point so no hour at exactly that temperature is left
uncovered (seen with 1 K bins).
- Average the duration curve between sample points instead of picking
single hours, which showed hot water hours as spikes.
- Make the hidden attribute override label display rules.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Diffstat (limited to 'README.md')
| -rw-r--r-- | README.md | 52 |
1 files changed, 37 insertions, 15 deletions
@@ -4,31 +4,44 @@ Like BWP WPsim, but for every German postcode. Hourly DWD air temperatures 2007â (about 470 stations, nearest station per postcode) drive a simple model: - Heating load linear from Norm-Heizlast at Norm-Außentemperatur to 0 at the heating limit. -- Heat pumps: Remko LWM 80/110/150 with maximum capacity and COP per outdoor and flow - temperature (W35/W45/W55) from the installation manual, see `web/devices.js`. The - bivalence point follows from capacity and load; in bivalent-alternativ mode it is a - manual switching temperature. Load the heat pump cannot cover above it is shown as - uncovered. Hours below the minimum capacity are counted as cycling. +- Heat pumps: Remko LWM 80/110/150 (installation manual) and Panasonic Aquarea generation J + (WH-MDC05/07/09J3E5) and generation L (WH-WDG05/07/09LE5, service manual heating + capacity tables) with maximum capacity and COP per outdoor and flow temperature + (W35/W45/W55), see `web/devices.js`. The bivalence point + follows from capacity and load; in bivalent-alternativ mode it is a manual switching + temperature. Load the heat pump cannot cover above it is shown as uncovered. Hours below + the minimum capacity are counted as cycling (Remko only; Panasonic does not publish it). - Generic heat pump: capacity equals the load at a manual bivalence point and changes by a fixed %/K; COP of the LWM 110 (air) or Carnot-based (ground/water). - Modes: monovalent (heater rod), bivalent-parallel (optional cut-off temperature), bivalent-alternativ. Flow temperature fixed or weather-compensated. +- Inputs in five steps (location, building, heat pump, hot water & PV, costs), then the + full results; the key figures stay visible above every step and update live. - Backup fuel: heater rod, natural gas, LPG, oil, pellets or firewood, with amounts in kWh, m³, l, kg or rm. -- Results: heat demand, coverage shares, JAZ, electricity, costs; charts and CSV export. +- Optional hot water and PV, each switched on separately (step 4, results in their own section): + - Hot water: daily demand charged from 11 to 15 h MEZ at tank temperature + 5 K, with + priority over heating; the backup heater covers what the heat pump cannot. + - PV: hourly yield from DWD 10-minute global and diffuse irradiation (nearest solar + station per year), south, 30° tilt, Hay-Davies transposition, 14 % losses, module + temperature from the air temperature. Inputs are only kWp and battery kWh (90 % round + trip, 1 C) and whether surplus is fed in (otherwise curtailed). PV and battery supply + the heat pump and heater rod only, no household load. +- Results: heat demand, coverage shares, JAZ, electricity, self-consumption, autarky, + costs; charts and CSV export. The app is static HTML/JS; all calculations run in the browser. ## Quick start Requires [uv](https://docs.astral.sh/uv/). The weather data is not part of this -repository. Build it once from the original sources (downloads about 700 MB into -`.cache/`, writes about 150 MB to `web/data/`, takes a few minutes): +repository. Build it once from the original sources (downloads about 1.9 GB into +`.cache/`, writes about 190 MB to `web/data/`, takes about 30–60 minutes): ```sh uv run scripts/prep.py ``` -uv picks a suitable Python and installs the script's dependencies (numpy) from the +uv picks a suitable Python and installs the script's dependencies (numpy, pandas) from the metadata at the top of `scripts/prep.py`. Then serve the `web/` directory and open http://127.0.0.1:8765: @@ -49,17 +62,26 @@ fetch fresh data (for example after DWD publishes a new year). 3. Estimates the Norm-Außentemperatur per station as the two-day mean undercut on 10 days in 20 years. This is within about 0.5–2.5 K of the DIN/TS 12831-1 values (usually warmer); the user can override it. -4. Downloads [GeoNames postal codes](https://download.geonames.org/export/zip/) and assigns +4. Downloads the 10-minute solar archives from + [DWD](https://opendata.dwd.de/climate_environment/CDC/observations_germany/climate/10_minutes/solar/historical/), + sums them to hours (UTC, all six values required) and keeps years with global + irradiation under the same gap limits; missing hours are filled from the same hour of the + surrounding days, missing diffuse values with the Erbs correlation. Stations that only + record sunshine duration are skipped. The PV yield per kWp is computed here and written + to `web/data/pv/`; each temperature station uses the nearest solar station per year. +5. Downloads [GeoNames postal codes](https://download.geonames.org/export/zip/) and assigns each postcode to its nearest station. ## Limitations - No altitude correction between postcode and station. -- JAZ ignores cycling, circulation pump and hot water, so it is on the optimistic side. +- JAZ ignores cycling, circulation pump and tank losses beyond the hot water demand entered, + so it is on the optimistic side. +- PV orientation is fixed; the battery starts empty every year and is not charged from the grid. - Device data is full load at nominal conditions; part load, defrost beyond the datasheet - points and other devices are not modelled. Capacities were digitised from the manual's + points and other devices are not modelled. Remko capacities were digitised from the manual's diagrams (about ±0.2 kW). -- Not affiliated with BWP, Remko or DWD. +- Not affiliated with BWP, Remko, Panasonic or DWD. ## License and data sources @@ -67,7 +89,7 @@ Code: [MIT](LICENSE). The generated data is subject to its sources' terms: -- Weather data: Deutscher Wetterdienst (DWD), Climate Data Center, hourly air temperature, - see the [DWD terms of use](https://opendata.dwd.de/climate_environment/CDC/Terms_of_use.pdf). +- Weather data: Deutscher Wetterdienst (DWD), Climate Data Center, hourly air temperature + and 10-minute solar irradiation, see the [DWD terms of use](https://opendata.dwd.de/climate_environment/CDC/Terms_of_use.pdf). Attribution: "Datenbasis: Deutscher Wetterdienst". - Postcodes: [GeoNames](https://www.geonames.org/), CC BY 4.0. |