# Deckungsanteil Wärmepumpe Like BWP WPsim, but for every German postcode. Hourly DWD air temperatures 2007–2025 (about 470 stations, nearest station per postcode) drive a simple model: - Heating load linear from Norm-Heizlast at Norm-Außentemperatur to 0 at the heating limit. - Heat pump capacity equals the load at the (manual) bivalence point and changes by a fixed %/K with outdoor temperature. Modes: monovalent, bivalent-parallel (optional cut-off temperature), bivalent-alternativ. - COP from the Remko LWM 110 datasheet (A−7/A2/A7 at W35), transferred to other flow temperatures via the Carnot efficiency; flow temperature fixed or weather-compensated. - Backup fuel: heater rod, natural gas, LPG, oil, pellets or firewood, with amounts in kWh, m³, l, kg or rm. - Results: heat demand, coverage shares, JAZ, electricity, costs; charts and CSV export. The app is static HTML/JS; all calculations run in the browser. ## Quick start The weather data is not part of this repository. Build it once from the original sources (needs Python ≥ 3.10 and numpy; downloads about 700 MB into `.cache/`, writes about 150 MB to `web/data/`, takes a few minutes): ```sh python3 -m venv .venv && .venv/bin/pip install numpy .venv/bin/python scripts/prep.py ``` Then serve the `web/` directory and open http://127.0.0.1:8765: ```sh python3 -m http.server 8765 -d web ``` Re-running `scripts/prep.py` reuses the downloads in `.cache/`; delete that directory to fetch fresh data (for example after DWD publishes a new year). ## What `scripts/prep.py` does 1. Downloads the station list and hourly air temperature archives (`historical/`) from the [DWD Climate Data Center](https://opendata.dwd.de/climate_environment/CDC/observations_germany/climate/hourly/air_temperature/historical/). 2. Keeps years with at most 3 % missing hours and no gap over 72 h (gaps are interpolated) and stations with at least 10 such years. 3. Estimates the Norm-Außentemperatur per station as the two-day mean undercut on 10 days in 20 years. This is within about 0.5–2.5 K of the DIN/TS 12831-1 values (usually warmer); the user can override it. 4. Downloads [GeoNames postal codes](https://download.geonames.org/export/zip/) and assigns each postcode to its nearest station. ## Limitations - No altitude correction between postcode and station. - JAZ ignores cycling, circulation pump and hot water, so it is on the optimistic side. - LWM 110 datasheet values were taken from retailer listings; check them against the manufacturer's datasheet. - Not affiliated with BWP, Remko or DWD. ## License and data sources Code: [MIT](LICENSE). The generated data is subject to its sources' terms: - Weather data: Deutscher Wetterdienst (DWD), Climate Data Center, hourly air temperature, see the [DWD terms of use](https://opendata.dwd.de/climate_environment/CDC/Terms_of_use.pdf). Attribution: "Datenbasis: Deutscher Wetterdienst". - Postcodes: [GeoNames](https://www.geonames.org/), CC BY 4.0.