<title>Add Panasonic Aquarea, hot water and PV, step-by-step layout</title>
<updated>2026-11-08T14:20:31Z</updated>
<author>
<name>Louis</name>
<email>louis@dnge.de</email>
</author>
<published>2026-11-08T14:20:31Z</published>
<link rel='alternate' type='text/html' href='https://git.dnge.de/deckungsanteil/commit/?id=5a956f1c82b10f4283fa8bbfd52fd9c6c2a39bd9'/>
<id>urn:sha1:5a956f1c82b10f4283fa8bbfd52fd9c6c2a39bd9</id>
<content type='text'>
- Panasonic Aquarea J (WH-MDC05/07/09J3E5) and L (WH-WDG05/07/09LE5)
  monobloc capacity and COP tables from the service manuals.
- Optional hot water (daily demand charged 11-15 h MEZ with priority over
  heating) and PV with battery from DWD 10-minute global/diffuse irradiation,
  each switched on separately; surplus fed in or curtailed.
- Inputs in five steps with the key figures always visible on top and the
  matching chart beside each step; full results in the last step.
- Bisect the bivalence point so no hour at exactly that temperature is left
  uncovered (seen with 1 K bins).
- Average the duration curve between sample points instead of picking
  single hours, which showed hot water hours as spikes.
- Make the hidden attribute override label display rules.

Co-Authored-By: Claude Opus 5.5 &lt;noreply@anthropic.com&gt;
</content>
</entry>
<entry>
<title>Add Remko LWM 80/110/150 capacity and COP curves</title>
<updated>2026-11-06T15:58:13Z</updated>
<author>
<name>Louis</name>
<email>louis@dnge.de</email>
</author>
<published>2026-11-06T15:58:13Z</published>
<link rel='alternate' type='text/html' href='https://git.dnge.de/deckungsanteil/commit/?id=bcfbc9630d5c052a23b8bfe205d11d0ba3feac41'/>
<id>urn:sha1:bcfbc9630d5c052a23b8bfe205d11d0ba3feac41</id>
<content type='text'>
Capacity (n-max) and COP per outdoor and flow temperature from the
installation manual. With a device the bivalence point follows from
capacity and load (manual switching temperature in alternative mode);
load not covered above it is reported separately, cycling hours below
the minimum capacity are counted.

Co-Authored-By: Claude Opus 5.5 &lt;noreply@anthropic.com&gt;
</content>